Wed, 08 Feb 2012 20:07:00 +0200
Update version, adapt patch, correct PID writing, correct build on newer
FreeBSD releases, and most importantly introduce new patch to try to
avoid segfault caused by multiple network interfaces with the same (or
no) address. This is common when configuring bridges and tunnels.
1 #!@l_prefix@/bin/openpkg rc
2 ##
3 ## rc.dovecot -- Run-Commands
4 ##
6 %config
7 dovecot_enable="$openpkg_rc_def"
8 dovecot_log_prolog="true"
9 dovecot_log_epilog="true"
10 dovecot_log_numfiles="10"
11 dovecot_log_minsize="1M"
12 dovecot_log_complevel="9"
13 dovecot_deliver_log_prolog="true"
14 dovecot_deliver_log_epilog="true"
15 dovecot_deliver_log_numfiles="10"
16 dovecot_deliver_log_minsize="1M"
17 dovecot_deliver_log_complevel="9"
19 %common
20 dovecot_pidfile="@l_prefix@/var/dovecot/run/master.pid"
21 dovecot_signal () {
22 [ -f $dovecot_pidfile ] && kill -$1 `cat $dovecot_pidfile`
23 }
25 %status -u @l_susr@ -o
26 dovecot_usable="unknown"
27 dovecot_active="no"
28 rcService dovecot enable yes && \
29 dovecot_signal 0 && dovecot_active="yes"
30 echo "dovecot_enable=\"$dovecot_enable\""
31 echo "dovecot_usable=\"$dovecot_usable\""
32 echo "dovecot_active=\"$dovecot_active\""
34 %start -u @l_susr@
35 rcService dovecot enable yes || exit 0
36 rcService dovecot active yes && exit 0
37 @l_prefix@/sbin/dovecot
39 %stop -u @l_susr@
40 rcService dovecot enable yes || exit 0
41 rcService dovecot active no && exit 0
42 dovecot_signal TERM
43 sleep 2
44 rm -f $dovecot_pidfile >/dev/null 2>&1 || true
46 %restart -u @l_susr@
47 rcService dovecot enable yes || exit 0
48 rcService dovecot active no && exit 0
49 rc dovecot stop start
51 %reload -u @l_susr@
52 rcService dovecot enable yes || exit 0
53 rcService dovecot active no && exit 0
54 dovecot_signal HUP
56 %daily -u @l_susr@
57 rcService dovecot enable yes || exit 0
58 rcTmp -i
59 hintfile=`rcTmp -f -n hint`
60 shtool rotate -f \
61 -n ${dovecot_log_numfiles} -s ${dovecot_log_minsize} -d \
62 -z ${dovecot_log_complevel} -m 600 -o @l_susr@ -g @l_sgrp@ \
63 -P "${dovecot_log_prolog}" \
64 -E "${dovecot_log_epilog}; echo 1 >$hintfile" \
65 @l_prefix@/var/dovecot/log/dovecot.log
66 if [ -s $hintfile ]; then
67 dovecot_signal USR1
68 fi
69 rcTmp -k
70 shtool rotate -f \
71 -n ${dovecot_deliver_log_numfiles} -s ${dovecot_deliver_log_minsize} -d \
72 -z ${dovecot_deliver_log_complevel} -m 600 -o @l_rusr@ -g @l_rgrp@ \
73 -P "${dovecot_deliver_log_prolog}" \
74 -E "${dovecot_deliver_log_epilog}" \
75 @l_prefix@/var/dovecot/log/deliver.log