Wed, 08 Feb 2012 20:07:00 +0200
Update version, adapt patch, correct PID writing, correct build on newer
FreeBSD releases, and most importantly introduce new patch to try to
avoid segfault caused by multiple network interfaces with the same (or
no) address. This is common when configuring bridges and tunnels.
1 #!@l_prefix@/bin/openpkg rc
2 ##
3 ## rc.stun -- Run-Commands
4 ##
6 %config
7 stun_enable="$openpkg_rc_def"
8 stun_bind_addr1="127.0.0.1"
9 stun_bind_addr2="127.0.0.2"
10 stun_bind_port1="3478"
11 stun_bind_port2="3479"
13 %common
14 stun_pidfile="@l_prefix@/var/stun/stun.pid"
15 stun_signal () {
16 [ -f $stun_pidfile ] && kill -$1 `cat $stun_pidfile`
17 }
19 %status -u @l_susr@ -o
20 stun_usable="unknown"
21 stun_active="no"
22 rcService stun enable yes && \
23 stun_signal 0 && stun_active="yes"
24 echo "stun_enable=\"$stun_enable\""
25 echo "stun_usable=\"$stun_usable\""
26 echo "stun_active=\"$stun_active\""
28 %start -u @l_susr@
29 rcService stun enable yes || exit 0
30 rcService stun active yes && exit 0
31 @l_prefix@/sbin/stund -b \
32 -h "${stun_bind_addr1}" \
33 -a "${stun_bind_addr2}" \
34 -p "${stun_bind_port1}" \
35 -o "${stun_bind_port2}" \
36 -P "${stun_pidfile}"
38 %stop -u @l_susr@
39 rcService stun enable yes || exit 0
40 rcService stun active no && exit 0
41 stun_signal TERM
42 sleep 2
43 rm -f $stun_pidfile >/dev/null 2>&1 || true
45 %restart -u @l_susr@
46 rcService stun enable yes || exit 0
47 rcService stun active no && exit 0
48 rc stun stop start